CBMZK - CR-166B COPYRAPID OFFSET DEVELOPER

  • MSDS: CBMZK
  • Manufacturer: AGFA CORP
  • Product Name: CR-166B COPYRAPID OFFSET DEVELOPER
  • National Stock Number: 6750-00N071035
Product Identification

Product ID:CR-166B COPYRAPID OFFSET DEVELOPER
MSDS Date:04/01/1991
FSC:6750
NIIN:00N071035
MSDS Number: CBMZK

Responsible Party
AGFA CORP
100 CHALLENGER RD
RIDGEFIELD PARK, NJ 07660
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 201-440-2500

Cage: HO790

Contractor
AGFA DIVISION, BAYER CORPORATION
RIDGEFIELD PARK, NJ 07660 US

Telephone: 201-440-2500

Cage: 0P7P7

Ingredients

SODIUM HYDROXIDE (CERCLA)

CAS: 1310-73-2

RTECS: WB4900000

Fraction By Weight: 1-5%

OSHA PEL 2 MG/M3

ACGIH TLV: C 2 MG/M3

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


HYDROQUINONE (SARA 302/313) (CERCLA)

CAS: 123-31-9

RTECS: MX3500000

Fraction By Weight: 1-5%

OSHA PEL 2 MG/M3

ACGIH TLV: 2 MG/M3

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


4-METHYL-1-PHENYL-3-PYRAZOLIDONE; (METHYLPHENIDONE)

CAS: 2654-57-1

Fraction By Weight: 0-1%

OSHA PEL N/K

ACGIH TLV: N/K


1)

CAS: 7757-83-7

RTECS: WE2150000

Fraction By Weight: 10-15%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE:MAY CAUSE SEVERE IRRITATION
AND BURNING. SKIN:MAY CAUSE SEVERE IRRITATION AND BURNS; MAY CAUSE
ALLERGIC SKIN REACTION. INHALATION:NORMALLY NO PROBLEM, BUT
INHALATION OF MIST COULD CAUSE RESP IRATORY IRRITATION.
INGESTION:MAY CAUSESEVERE IRRITATION OR BURNING OF THE MUCOUS
MEMBRANES OR (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:DIGESTIVE TRACT. (NOTE:PERTAINS TO
EACH INGRED LISTED PER 29 CFR SECT. 1910.1200). HYDROQUINONE:RPTD
CONT CAN CAUSE SKIN SENSIT & ALLERGIC DERM. CHRONIC OVEREXP CAN
CAUSE ANEMIA & DISCOLORATI ON & CORNEAL OPACITY OF EYES. METHYL
PHENIDONE:CONT W/SKIN MAY CAUSE SLIGHT IRRIT. LAB TESTS INDICATE
MATL IS (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES:IMMEDIATELY FLUSH W/PLENTY OF RUNNING WATER FOR @ LEAST
15 MINS. OBTAIN MEDICAL ATTENTION. SKIN:FLUSH AFFECTED AREAS
PROMPTLY W/WATER FOR 15 MINS. REMOVE CONTAMD CLTHG. IN CASE OF
CONTINUED IRRIT CONSULT PHYS. INHAL:REMOVE TO FRESH AIR.
INGEST:OBTAIN IMMEDIATE MEDICAL ATTENTION.

Fire Fighting

Flash Point:NONCOMBUSTIBLE
Extinguishing Media:ANY APPLICABLE TO PRIMARY CAUSE OF FIRE. MEDIA
SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . EVACUATE PERSONNEL TO A SAFE AREA. KEEP PERSONNEL
REMOVED & UPWIND OF FIRE.
Unusual Fire/Explosion Hazard:WHEN HEATED TO DECOMPOSITION EMISSION OF
TOXIC FUMES OF SO, IS POSSIBLE.

Accidental Release

Spill Release Procedures:NOTE:REVIEW FIRE & EXPLO HAZ DATA & SPEC PROT
INFO SECTIONS BEFORE PROCEEDING W/CLEAN UP. USE APPROP PERSONAL
PROT EQUIP DURING CLEAN UP. DIKE SPILL. PVNT LIQ FROM ENTERING
SEWERS, WATERWAYS/LOW AREAS . SOAK UP W/SAND, OIL DRY OR OTHER
ABSORB (SUPDAT)
Neutralizing Agent:SPILL MAY BE NEUTRALIZED WITH POWDERED CITRIC ACID.

Handling

Handling and Storage Precautions:STORE IN WELL VENTILATED AREA. KEEP
CONTAINER TIGHTLY CLOSED. DO NOT STORE WITH INCOMPATIBLE MATERIALS
(SEE REACTIVITY DATA SECTION).
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NONE NEEDED WITH WORKING MIXTURES AND NORMAL
ROOM VENTILATION. NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:ROOM VENTILATION IS SUFFICIENT. AVOID USE OF PRODUCT IN
UNVENTILATED AREAS.
Protective Gloves:CHEMICAL GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGG (SUPDAT)
Other Protective Equipment:APRONS. ANSI APPRVD EMERGENCY EYE WASH &
DELUGE SHOWER .
Work Hygienic Practices:DO NOT STORE OR CONSUME FOOD, DRINK OR TOBACCO
IN AREA WHERE THEY MAY BECOME CONTAMINATED WITH THIS MATERIAL.
Supplemental Safety and Health
VP:SAME AS WATER. VAP DENS:SAME AS WATER. EFTS OF OVEREXP:SKIN SENSIT.
SPILL RELEASE PROC:MATL. WASTE DISP METH:DISCHARGE TO SEWER
REQUIRES APPROVAL OF PERMITTING AUTHORITY & MAY REQ PRETREATMENT.
EYE PROT:& FULL LENGTH FACESHIELD .

Chemical Properties

Boiling Pt:B.P. Text:221F,105C
Vapor Pres:SUPDAT
Vapor Density:SUPDAT
Spec Gravity:1.142 (H*2O=1)
pH:>13
Evaporation Rate & Reference:SAME AS WATER
Solubility in Water:100%
Appearance and Odor:CLEAR AND LIGHT YELLOW LIQUID, NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF SULFUR, CO*2, CARBON
MONOXIDE.

Disposal

Waste Disposal Methods:DISP MUST BE I/A/W FED, STATE & LOC REGS .
RECOVER NONUSABLE FREE LIQ AND/OR CONTAMD WATER & DISPOSE OF IN
APPRVD & PERMITTED TREATMENT SYS. REMOVE NONUSABLE SOLID MATL
AND/OR CONTAMD SOIL, FOR DISP IN APPRVD & PERMITTED LANDFILL.
(SUPDAT)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.